(770) 300-0224The Batch Digester Liquor Analyzer Solution: This solution monitors black liquor composition in a batch digester providing a means for implementing advanced control schemes in the batch pulping process. The residual effective alkali (EA) profile is an indicator of exiting kappa number, the residual active alkali (AA) profile, lignin profile and total Dissolved solids (TDS) profiles are indicators of exiting pulp yield.
These time varying profiles can be correlated to the average kappa and yield of the exiting pulp or a mass balance model can be used to directly calculate kappa and yield during the course of the cooking process. Monitoring of the EA profile during temperature ramp up allows the alkali to wood ratio to be trimmed prior to sealing the digester, resulting in a more consistent charge of cooking chemicals for each cook. Black liquor composition contains a wealth of information relating to various pulp properties.
The DURALYZER-NIR analyzer captures
this information in the spectral signature of the black liquor
sample. So in addition to providing the previously mentioned
measurements, a variety of pulp properties (e.g. kappa number,
relative yield and viscosity) can be directly correlated to the
liquor spectral signature. Whatever advanced batch digester control
scheme is implemented requires reliable and accurate measurements.
The DURALYZER-NIR analyzer solution easily provides
these measurements in a timely and reliable manner.

Application Technology
The graphic above shows how the
DURALYZER-NIR digester analyzer is implemented on batch
digesters running a standard kraft cook. Each digester has a
dedicated sample line supplying the analyzer.
All samples flow from the process through the analyzer and directly
back into the process. One analyzer can support up to eight
different digesters.
Proprietary filters combined with a high
pressure backflush system ensure that line plugging due to chip
debris does not interfere with sample collection. Proprietary high
cycle life valves ensure that valve maintenance is not required for
two or more years. Black liquor REA, RAA, lignin & TDS are provided
for each connected digester.
DURALYZER-NIR .vs. Current Solutions
Current sensors for this application are the same as for the
continuous digester case and include hybrid systems composed of some
arrangement of a refractometer, conductivity meter and UV absorption
meter. Online titraters are another option for this application.
Titraters are limited to measuring only residual EA, however. A
major drawback to these hybrid systems is that each meter has to be
calibrated for the particular component that it will be measuring.
Additionally, since this sensor is a collection of single point
measurements it is susceptible to the same drift issues as
conductivity meters are for white liquor analysis.
Online titraters
can measure residual EA using an automated version of the manual
residual EA, however, this is usually the only measurement that
is available. Maintenance requirements for an online titrater are
also quite high for this application. The combination of limited
measurements and excessive maintenance requirements make it
difficult to justify the capital investment for a titration based
solution. The DURALYZER-NIR digester analyzer
solution provides the collection of measurements that the hybrid
sensor provides in one low maintenance, cost effective instrument.

Manufacturer: R.E. Hodges; Auburn, Alabama
Monitoring black liquor residual effective alkali (REA) and Lignin content in batch digesters provides a means for implementing advanced control schemes. NIR analysis is well suited for measuring these properties in the BL as well as the residual active alkali (RAA) and total Dissolved solids (TDS). The figure on the left shows typical sample collection points. In the first step of the control, the EA slope is measured and compared to the current calculated H-factor.
When the cooking temperature is stabilized, the EA measurement is compared to the corresponding final calculated H-factor. Using those two comparisons values, a new blow H-factor is calculated and the blow time is rescheduled based on this corrected H-factor target. Lignin measurements are used to fine tune the final H-factor model. This H-factor modeling improves kappa variability and stabilizes pulp quality resulting in: